Siemens Siprotec 4 SIPROTEC 7SA64 Protection Relay
The SIPROTEC 7SA64 distance protection relay is a universal relay for protection, control, and automation with a graphic display on the basis of the SIPROTEC 4 system. Also, Its high level of fleavailability.- Digitalizable to be implemented at all voltage levels. Additionally, with this relay, you are ideally equisaturation- Phase-segregatedrs security of investment and also saves on operating costs. In fact, High-speed tripping time-Impedance setting range allows very small settings for the protection of very short lines-Self-setting detection for power swing frequencies up to 7 Hz. Especially, the current transformer saturation detector prevents non-selective tripping by distance protection in the event of CT saturation.-Phase-segregated teleprotection for improved selectivity and availability-Digital relay-to-relay communication by means of an integrated serial protection data interface.- Adaptive auto-reclosure (ADT)
PROTECTION FUNCTIONS
- Non-switched distance protection with 6 measuring systems (21/21N)
- High resistance earth-fault protection for single and three-phase tripping (50N, 51N, 67N)
- In fact, Earth-fault detection in isolated and resonant-earthed networks
- Tele (pilot) protection (85)
- Fault locator (FL)
- Power-swing detection/tripping (68/68T)
- Phase-overcurrent protection (50/51)
- Clearly, Switch-onto-fault protection (50HS)
- STUB bus overcurrent protection (50STUB)
- Overvoltage/undervoltage protection (59/27)
- Over/underfrequency protection (81O/U)
- Auto-reclosure (79)
- Synchro-check (25)
- Breaker failure protection (50BF)
- Thermal overload protection (49)
CONTROL FUNCTIONS
- Commands for control of c.b. and isolators
MONITORING FUNCTIONS
- Trip circuit supervision (74TC)
- Self-supervision of the relay
- Measured-value supervision
- Event logging
- Fault logging
- Oscillographic fault recording
- Switching statistics
FRONT DESIGN
- Easy operation with numeric keys
- Function keys
- LEDs for local alarm
- PC front port for convenient relay setting
COMMUNICATION INTERFACES
- Overall, Front interface for connecting a PC
- After that, System interface for connecting to a control system via various protocols
– IEC 60870-5-103 protocol
– PROFIBUS-FMS/-DP
– DNP 3.0
– IEC 61850 Ethernet - 1 serial protection data interface for teleprotection
- Rear-side service/modem interface
- Time synchronization via – IRIG-B or DCF 77 or – System interface
However, SIPROTEC 4 leads the way in integrating protection, control, measurement, and automation functions in one device. The homogenous system platform, the unique DIGSI 4 engineering program, and extensive experience of more than a million successfully operating devices in the field worldwide – thanks to these unique advantages, SIPROTEC 4 enjoys top recognition among users worldwide. Thus, SIPROTEC 4 is the industry standard for digital protection technology today in all fields of application.






Reviews